1. Thermal resistance
Thermal power P, the rate of heat transfer, plays the part of current. The temperature difference \Delta T plays the part of voltage. The thermal resistance R_{\text{th}} tells us how large a temperature difference is needed to transfer a given power. Its unit is kelvins per watt, \text{K/W}, or degrees Celsius per watt, ^\circ\text{C/W}.
At a steady temperature, when the thermal resistance can be treated as constant:
For 1 W through a thermal resistance of 40 K/W, the hot end is 40 degrees warmer than the cold end. During warm-up, the component also stores thermal energy. This steady equation alone cannot tell us how fast its temperature rises.
2. Following the heat
For a component mounted on a heatsink (a part that helps transfer heat to the surrounding air), an important path can run from the interior to the package, across the mounting interface, and from the heatsink to the air. If nearly all the power passes along this path, add the three thermal resistances:
- j-c runs from the hot interior to the case. In a semiconductor the term is junction to case.
- c-h runs from the case to the heatsink. Mounting pressure and the interface material affect it.
- h-a runs from the heatsink to the ambient air.
The hot temperature in this model is:
The letter j labels the hot point in the figure. Use the actual temperature point defined in the resistor’s data sheet. Heat can also reach the air or board by paths in parallel through the leads, the package or the copper on the board.
3. Three limits to look up
A. The power derating curve
A derating curve shows how the permissible power changes with the specified temperature. In this example the figure allows the full rated power up to 70 °C, then falls linearly to zero at 155 °C. For a 0.25 W resistor at 110 °C under those conditions:
Read what the horizontal axis means for the chosen part. It may be room temperature, case temperature or a temperature measured at a specified point on the board.
B. Maximum working voltage
For a 1 MΩ resistor rated at 0.25 W, the power formula alone would predict:
If the data sheet gives a maximum working voltage of 250 V, that limit applies as well. The insulation and resistive film can fail at excessive voltage even while the calculated power remains permissible. Check the derated power limit and the working voltage limit and use the more restrictive of the two. This is a calculation example.
C. Temperature coefficient of resistance
The temperature coefficient of resistance (TCR) describes how much the resistance changes with temperature. The data sheet commonly gives it in parts per million per degree Celsius, \text{ppm}/^\circ\text{C}. Over a range where a linear approximation holds:
Here R_0 is the resistance before the temperature change and \alpha is the TCR converted to a fraction per degree. A limit of \pm350\ \text{ppm}/^\circ\text{C} gives \alpha=\pm350\times10^{-6}/^\circ\text{C}, so a 100 °C change can shift the resistance by as much as about \pm3.5\% in this model. A precision part may specify \pm10 or \pm50\ \text{ppm}/^\circ\text{C}. Check its data sheet.
D. A current-sensing shunt
A shunt for measuring current is a small resistance in series with the circuit. The instrument measures its voltage and calculates I=U/R. With a 0.01 Ω shunt carrying 10 A, the voltage is 0.10 V and the power is:
That watt of power can heat the shunt enough to change its resistance. If the instrument still uses 0.01 Ω in the calculation, the reported current drifts. Precision shunts use low-TCR alloys such as suitable grades of manganin and specify mounting conditions. Resistance tolerance, connections and thermoelectric voltages can affect the reading too.
A real shunt also has stray inductance, an unwanted inductive effect caused by the part and its connections. A simple model for the voltage is:
The derivative \mathrm di/\mathrm dt measures how fast the current changes from instant to instant. In pulse-width modulation, or PWM, the circuit switches the supply in pulses and varies their duration to control the average effect. A steep current edge can produce a voltage spike larger than the voltage we wanted to measure across the resistance. A low-inductance shunt and suitable connections help keep those spikes smaller.
4. Pulses and continuous heating
A capacitor charging or a motor braking can put short bursts of energy into a resistor. To find the energy in one pulse, integrate the power (add up its energy contributions over the duration of the pulse):
For a rectangular pulse with constant power, this is E=P_{\text{pulse}}t_{\text{pulse}}. If the pulse is short compared with the time needed for heat to spread, much of its energy initially stays in the component. The durations that matter depend on the resistor and how it is mounted.
For regular pulses, check the peak voltage, the pulse energy or permissible pulse power, the repetition rate and the average power. For an ideal fixed resistor:
The RMS current is the constant DC current that would heat the same resistor at the same average rate. This check covers average heating. Use the data sheet’s separate pulse and voltage limits for the brief peaks.
5. Specialised resistors
- Current-sensing shunts use low resistances, for example 0.001–0.1 Ω, and materials chosen to keep the reading stable. A TCR below 20 ppm/°C is a specification of some parts.
- Braking resistors absorb energy that a drive returns when slowing a motor. An RC snubber is a network that damps unwanted oscillations or voltage spikes. Resistors for either application must be chosen for the actual pulse and mounting conditions.
- A flameproof resistor is built to resist the spread of flame under specified conditions. A fusible resistor is specified to open under certain overloads. Check which property the part actually has.
6. Thermal calculations
Each exercise uses a steady thermal model and assumed data.
Exercise 1 — In free air
A part dissipates 0.5 W. Its thermal resistance to 25 °C air is 150 K/W. Its temperature rise is 150\times0.5=75 degrees, so the point modelled reaches 100 °C. Check both the power and the relevant temperature limit before judging whether this is permitted.
Exercise 2 — On a heatsink
A power resistor dissipates 20 W with a total thermal resistance of 3 K/W to 30 °C air. The rise is 3\times20=60 degrees. The point modelled reaches 90 °C. A surface at that temperature can burn skin.
Exercise 3 — Maximum power at a specified temperature
For 25 °C air, a 125 °C limit and 100 K/W, the maximum rise is 100 degrees. The thermal model gives 100/100=\mathbf{1\ \text{W}}. The component’s other ratings can make the allowed power lower.
7. Historical note — Fourier and heat flow
Joseph Fourier (1768–1830) published Théorie analytique de la chaleur in 1822. In conduction, heat flows towards cooler regions. Fourier’s law relates the heat flow to the temperature gradient, the rate at which temperature changes over distance. For a simple shape in steady conditions, this relationship leads to the thermal resistance model used in this lesson.

Visual reconstruction generated with AI for teaching purposes. It is not a historical archive document.
Previous lesson — series and parallel · Module plan · Next module — Kirchhoff’s laws (in French)