1. Why the connection matters
A voltmeter measures the difference in potential between two points and goes in parallel. Many digital meters have an input resistance around 10 MΩ on DC voltage ranges. The value depends on the instrument and range. The voltmeter draws a small current of its own.
An ammeter measures the rate at which electric charge crosses a section of the circuit. The entire current being measured passes through the meter:
The derivative \mathrm dQ/\mathrm dt measures how fast the amount of charge passing the section changes from instant to instant.
The meter’s resistance and burden voltage
A shunt is a small resistance inside the meter. The meter uses the voltage across the shunt to determine the current. The shunt, fuse, contacts and leads together produce a small voltage drop called the burden voltage. In a low-voltage circuit it can alter the current you set out to measure.
2. Two very different connections
In a series connection, the load and the meter share one path. For a positive DC reading, conventional current enters the selected current socket and leaves through COM. The circuit must limit the current to a value the meter and leads can handle.
Across a supply, the ammeter provides a very low-resistance path. The resulting current is limited mainly by the supply, leads and meter. An automotive battery or a high-current supply can produce a destructive current or an arc. A fuse can help only within its specified breaking capacity (the largest fault current it can safely interrupt). Some meters have unfused inputs.
3. Four steps at the bench
- Switch off and disconnect the supply. Estimate the current, check the meter’s limits and select the appropriate socket and range. Put the black lead in COM and the red lead in the correct current socket. Select DC or AC to suit the circuit.
- Open the circuit in the branch where you want the current reading.
- Insert the meter in series. Its two leads bridge the opening you just made, so the current in that branch will pass through the meter.
- Switch on and take the reading. Switch off and disconnect the supply again before removing the meter. Restore the original connection and return the red lead to the voltage and resistance socket.
Important
A lead left in the mA or A socket can short the next circuit you try to measure on the voltage setting. Physically move the lead back. The selector alone may leave that socket connected to the shunt.
4. Sockets, ranges and limits
Check that the expected current is within the instrument’s capabilities before selecting a current range. Start on a suitable higher range if the expected current is uncertain. Once you have a reading of, for example, 0.015 A (15 mA), power down before moving the lead to a suitable milliampere input for better resolution. Changing range can change the burden voltage.
High-current ranges may have a time limit and a required cooling interval. Read the manual for your meter. Check the voltage, current and measurement category (CAT rating) of the meter and its leads. A current clamp can measure current around a single conductor without breaking the circuit, provided it is suitable for the current type, range and category.
5. If the display reads zero or OL
Zero can mean no current, an open circuit, the wrong setup, a poor connection or an open fuse. OL usually indicates an overload or over-range condition, depending on the model and mode. Consult the manual before attributing either reading to a fault.
Disconnect the meter completely before checking a fuse. Some models permit a check with a second meter while the fuse is fitted. Follow the model’s procedure. If it calls for a removed fuse, an intact fuse generally shows a low resistance and a blown fuse shows an open circuit. Replace it with the exact type specified, including its current rating, voltage rating, speed, dimensions and breaking capacity. Keep the fuse in the protective path.
At a glance
| Voltage measurement | Direct current measurement | |
|---|---|---|
| Connection | Across two points, in parallel | In the path, in series |
| Input resistance | High | Low |
| Quantity | Potential difference, V | Charge per second, A |
| Red lead | Voltage and resistance socket | Suitable current socket |
| Before changing connections | Switch off where the procedure requires it | Switch off and disconnect the circuit supply |
| At the end | Leave the instrument ready for safe use | Return the red lead to the voltage and resistance socket |
© Sébastien Debucquoi — All rights reserved.